适用范围适用于楼宇自动化与智能控制系统、防盗报警与门禁系统、智能家居、机械仪表及需采用屏蔽抗干扰信号电缆的电子设备。额定交流电压 U0/U 300/300V 或以下。
备注- 材料:导体为高纯度无氧铜绞线;绝缘与护套为环保型聚氯乙烯(PVC);屏蔽为铝箔与高密度镀锡铜编织网相结合。
- 标准:JB/T8734.5-2016。额定电压:U0/U 300/300V。
运行特性- 长期工作温度:≤ 70℃
- 电缆敷设环境温度:≥ 0℃
- 弯曲半径(柔性电缆):D < 25 mm → ≥ 4D;D ≥ 25 mm → ≥ 6D
- 结构:导体 + 绝缘(两层结构)
参数表Specification (mm²) | Conductor Structure (n/mm) | Insulation Thickness (mm) | Sheath thickness (mm) | Finished product outer diameter (mm) | Conductor Resistance at 20℃ (Max, Ω/km) | Insulation Resistance at 70℃ (Min, MΩ·km) | Current - Carrying Capacity Reference Value A
2*0.12 | 7/0.15 | 0.4 | 0.6 | 3.8 | 158.0 | 0.016 | 1.0
2*0.2 | 12/0.15 | 0.4 | 0.6 | 4.3 | 92.3 | 0.013 | 2.0
2*0.3 | 16/0.15 | 0.5 | 0.6 | 5.1 | 69.2 | 0.014 | 3.0
2*0.5 | 16/0.20 | 0.5 | 0.6 | 5.8 | 39.0 | 0.013 | 5.0
2*0.75 | 24/0.20 | 0.5 | 0.6 | 6.2 | 26.0 | 0.012 | 7.0
2*1.0 | 32/0.20 | 0.6 | 0.7 | 7.2 | 19.5 | 0.010 | 11.0
2*1.5 | 48/0.20 | 0.7 | 0.8 | 7.9 | 13.3 | 0.009 | 17.0
2*2.5 | 49/0.25 | 0.8 | 1.0 | 9.7 | 7.98 | 0.009 | 26.0
2*4.0 | 81/0.25 | 0.8 | 1.2 | 11.3 | 4.95 | 0.007 | 35.0
3*0.12 | 7/0.15 | 0.4 | 0.6 | 4.3 | 158.0 | 0.016 | 1.0
下载提供数据表(PDF)。
技术规格- 系列:RVVP(屏蔽 PVC 绝缘柔性信号电缆)。
- 额定电压:U0/U 300/300V。
- 标准:JB/T8734.5-2016。
- 导体:高纯度无氧铜,绞线(导体结构见参数表)。
- 绝缘 / 护套:环保型 PVC 作为绝缘和外护套材料。
- 屏蔽:铝箔与高密度镀锡铜编织网组合,提供抗电磁干扰保护。
- 工作温度(长期):≤ 70℃;敷设环境温度 ≥ 0℃。
- 弯曲半径(柔性电缆):D < 25 mm → ≥ 4D;D ≥ 25 mm → ≥ 6D。
- 典型电气/机械数据:导体电阻、绝缘电阻及电流承载参考值在参数表中给出,适用于 2×0.12 mm² 至 2×4.0 mm²(及 3×0.12 mm²)。
- 结构说明:导体 + 绝缘(两层结构)。